High Power Outdoor Waterproof IP66 50W 60W 100W 120W 150W180W 200W240W 250W 300W Nova II Tunnel Stadium Plaza Square LED Floodlight
IP66 LED Flood Light Fixture
Power: 50Watts
Input: AC 100-277V, 50/60Hz
Luminous Flux: 150lm/w±5%
CRI: >70/80ra
PF: >0.95
Lifespan: >=50000Hrs
IP rate: IP66
CCT: 3000/4000/6000K
Material: ADC12 Alu.+PC+Metal
Product Name |
MF-SDD |
Power |
50-300W |
Input Voltage |
AC100-277V 50/60Hz |
Output Voltage |
DC45V |
IP Rating |
IP66 |
Luminous Flux |
150LM/W |
CCT |
3000-6000K |
CRI |
Ra=>70/80 |
Body color |
Sliver |
Beam Angle |
25° 45° 60° 90° 80*150° 90*120° |
Fixture Material |
ADC12 Alu.+PC+Metal |
Lens Material |
Polycarbonate |
Dimmable Options |
0-10v, Dali, Sensor, LoRa, Zhaga |
Power Supply |
Mean Well |
Operating Temperature |
-40°C to 50°C |
Lifespan |
Hours >50000 |
Driver Efficiency |
>90% |
THD |
<15% |
Warranty |
5 years |
Experience superior lighting performance with the Nova Flood Light from Mingfeng Lighting. Built with advanced technology, this flood light boasts an IP66 waterproof and dustproof rating, ensuring durable and reliable use even in harsh outdoor environments.
The Nova Flood Light's die-casting heat sink provides optimal thermal management and a compact structure, making it highly efficient and long-lasting. Its racked angle design allows for precise installation, with up to 270 degrees of adjustability for maximum flexibility.
With easy installation and replacement features, the Nova Flood Light is also highly convenient and easy to maintain. Each single module provides up to 50W or 60W of power, and up to 5 modules can be combined into 300W, providing a range of options for lighting applications.
The Nova Flood Light also offers a range of photometry options, including symmetrical 30°/45°/60°/90° and asymmetric 150°*80°/120°*90°, enabling customized lighting angles and coverage areas.
Finally, the Nova Flood Light features a low total harmonic distortion (THD) of less than 15%, ensuring that it does not interfere with other electrical equipment while in use.
Invest in the Nova Flood Light from Mingfeng Lighting for superior lighting performance and long-lasting durability.
-
Die Casting Heat Sink: Excellent Thermal Management & Compact Structure
-
High Strength Polycarbonate Lens: Realize In IK08 Tempered Glass Cover Option: To Apply In Harsh Conditions
-
Single Module 50W/60W, Up To 5 Modules Can Be Combined Into 300W
-
Embedded Cable Raceway: Optimize Cable Layout
-
Racked Angle: Allows For Precise Installation, Up To 270°
-
"4mm Thickness L Shape Bracket: Wind Resistant Rate 17
-
Photometry: Symmetrical 30°/45°/60°/90°, Asymmetric 150°*80°/120°*90°
Application |
Examples |
Commercial Lighting |
Tunnels, Supermarkets, Large retailers, Schools, Billboards, Buildings, etc. |
Public Lighting |
Tunnels, Airports, Stadiums, Train stations, Bus stations, etc. |
Industrial Lighting |
Manufacturing facilities, Warehouses, Parking lots, Exhibition centers, Gas stations, Toll stations, etc. |
The Nova Flood Light from Mingfeng Lighting is a versatile lighting solution that can be used in a wide range of outdoor applications. Here are some examples of where the Nova Flood Light can be utilized:
1. Outdoor Parking Lots: The Nova Flood Light's photometry options and high lumen output make it an ideal solution for lighting up large outdoor parking lots.
2. Building Facades: With its precise installation angle and sleek design, the Nova Flood Light can be used to highlight the architecture of buildings and create a dramatic lighting effect.
3. Sports Fields: The Nova Flood Light's high-performance technology and symmetrical/asymmetrical photometry options make it a great choice for lighting up outdoor sports fields, providing optimal visibility for players and spectators.
4. Outdoor Security Lighting: The Nova Flood Light's waterproof and dustproof rating, combined with its easy installation and replacement features, make it an excellent choice for outdoor security lighting applications.
5. Industrial Lighting: The Nova Flood Light's durable construction, efficient thermal management, and high lumen output make it a great choice for lighting up outdoor industrial areas such as factories, warehouses, and loading docks.
Before installing the lighting fixtures, please read this instruction manual carefully.
1. The lighting fixtures should be installed, connected and tested by a certified electrician based
on the local regulations.
2. Lamps should always be installed or replaced carefully.
3. Please check the local voltage in accordance with the product requirements before installation.
4. Revamping only can be done when the power is off and the lamp is completely cooled down.
5. When clean the lamp, make the power off and let it cool down completely, clean the
fixture with a soft cloth and a standard PH neutral detergent, stainless steel should
be maintained regularly.
6. Don't cover the fixtures with flammable materials.
7. Replace should be made by the manufacturer or his service agent or certified electrician
in order to avoid a hazard.